6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixtures and Vacu-Pass Portal

 6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixtures and Vacu-Pass Portal

Catalog Number: 303681000

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: U.S. and Canada
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 6'
  • Power Cord & Plug: North America, 115 volts, 20 amps
  • Sash Opening: 8"

6' XPert Balance Enclosure with Guardian 1000 Digital Airflow Monitor

 6' XPert Balance Enclosure with Guardian 1000 Digital Airflow Monitor

Catalog Number: 3971622

  • Region: International
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: No

6' XPert Filtered Balance Station with Guardian Airflow Monitor

 6' XPert Filtered Balance Station with Guardian Airflow Monitor

Catalog Number: 3946621

  • Region: International
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: Yes

6' XPert Filtered Balance System with Guardian Airflow Monitor

 6' XPert Filtered Balance System with Guardian Airflow Monitor

Catalog Number: 3950621

  • Region: International
  • Blower Requirements: Contains built-in blower and exhaust HEPA filter
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: Yes

8' Protector Echo Filtered Floor-Mounted Fume Hood, 115V, 37.7" deep, 2 Fixtures

 8' Protector Echo Filtered Floor-Mounted Fume Hood, 115V, 2 Fixtures

Catalog Number: 183817001

  • Nominal Width: 8'
  • Sash Movement Direction: Vertical Rising
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Floor-Mounted

3' Purifier Logic+ Class II A2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixture, Vacu-Pass Portal and Base Stand

 Logic Plus A2 with stand 800

Catalog Number: 302381130

  • Base Stand: Included
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 3'
  • Power Cord & Plug: Schuko, 230 volts
  • Sash Opening: 8"

4' PuriCare Procedure Station with 10" sash opening

 4'  PuriCare Procedure Station with 10" sash opening

Catalog Number: 312410000

  • Region: U.S. and Canada
  • Built-In Options: None
  • Light Fixtures: Fluorescent
  • Nominal Exterior Width: 4' (122 cm)
  • Power Cord & Plug: 115 volts, 15 amps
  • Primary Application: Special procedures such as anesthesia delivery
  • Service Fixtures: No
  • Working Sash Height: 10" (25 cm)

4' Purifier Axiom C1 Biological Safety Cabinet, 230V UK

 4' Purifier Axiom C1 Biological Safety Cabinet, 230V UK

Catalog Number: 304480050

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type C1 Biosafety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Nominal Width: 4'
  • Power Cord & Plug: British (UK), 230 volts
  • Sash Opening: 8"

4' Purifier Cell Logic+, Class II A2 with Scope-Ready, Service Fixture, Vacu-Pass and Base Stand

 Scope-Ready A2 Cell Logic+ with base stand

Catalog Number: 332491160

  • Base Stand: Included
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Microscope-Compatible, Tube & Cable Pass-Through
  • Nominal Width: 4'
  • Sash Opening: 9"

5' Purifier Horizontal Clean Bench with UV Light

 5' Purifier Horizontal Clean Bench with UV Light

Catalog Number: 3250020

  • Built-in Options: UV light, UV screen
  • Laminar Flow: Horizontal
  • Nominal Width: 5'
  • Region: U.S. and Canada
  • Power Cord & Plug: North America, 115 volts, 15 amps

6' Protector Echo Filtered Benchtop Hood, side windows 115V

 6' Protector Echo Filtered Benchtop Hood, side windows 115V

Catalog Number: 181610000

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Exterior Depth: 37.7" (95.8 cm)
  • Style: Benchtop

6' Protector Pass-Through Laboratory Hood, left window, 230V

 6' Protector Pass-Through Laboratory Hood, left window, 230V

Catalog Number: 113607020

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

6' Protector XL Benchtop Laboratory Hood with 2 services fixtures and 1 electrical duplex, 36" interior depth

 Protector XL Hood Line Art

Catalog Number: 111620002

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Electrical Duplexes: 1
  • Exterior Depth: 43.7" (111.0 cm)
  • Service Fixtures: 2
  • Style: Benchtop

6' Purifier Cell Logic+, Class II B2 with Scope-Ready, Service Fixtures, Vacu-Pass and Base Stand

 6' Purifier Cell Logic+, Class II B2 with Scope-Ready, Service Fixtures, Vacu-Pass and Base Stand

Catalog Number: 333681170

  • Base Stand: Included
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Microscope-Compatible, Tube & Cable Pass-Through
  • Nominal Width: 6'
  • Power Cord & Plug: India, 230 volts
  • Sash Opening: 8"

6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixtures and Vacu-Pass Portal

 6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixtures and Vacu-Pass Portal

Catalog Number: 303681070

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 6'
  • Power Cord & Plug: India, 230 volts
  • Sash Opening: 8"

6' XPert Balance Enclosure with Guardian Jr. Airflow Monitor

 6' XPert Balance Enclosure with Guardian Jr. Airflow Monitor

Catalog Number: 3971601

  • Region: U.S. and Canada
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: No

6' XPert Filtered Balance Station, Deep

 6' XPert Filtered Balance Station, Deep

Catalog Number: 3946630

  • Region: U.S. and Canada
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: Yes

6' XPert Filtered Balance System, Deep

 6' XPert Filtered Balance System, Deep

Catalog Number: 3950630

  • Region: U.S. and Canada
  • Blower Requirements: Contains built-in blower and exhaust HEPA filter
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: Yes

8' Protector Echo Filtered Floor-Mounted Fume Hood, 115V, 37.7" deep, 2 Fixtures 2R

 8' Protector Echo Filtered Floor-Mounted Fume Hood, 115V, 2 Fixtures 2R

Catalog Number: 183817002

  • Nominal Width: 8'
  • Sash Movement Direction: Vertical Rising
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Electrical Duplexes: 1
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Floor-Mounted

3' Purifier Logic+ Class II A2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixture, Vacu-Pass Portal and Base Stand

 Logic Plus A2 with stand 800

Catalog Number: 302381140

  • Base Stand: Included
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 3'
  • Power Cord & Plug: China/Australia, 230 volts
  • Sash Opening: 8"

4' PuriCare Procedure Station with 10" sash opening

 4'  PuriCare Procedure Station with 10" sash opening

Catalog Number: 312410020

  • Region: International
  • Built-In Options: None
  • Light Fixtures: Fluorescent
  • Nominal Exterior Width: 4' (122 cm)
  • Power Cord & Plug: 100 volts, 15 amps
  • Primary Application: Special procedures such as anesthesia delivery
  • Service Fixtures: No
  • Working Sash Height: 10" (25 cm)

4' Purifier Axiom C1 Biological Safety Cabinet, 230V UK

 4' Purifier Axiom C1 Biological Safety Cabinet, 230V UK

Catalog Number: 304410050

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type C1 Biosafety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Nominal Width: 4'
  • Power Cord & Plug: British (UK), 230 volts
  • Sash Opening: 10"

4' Purifier Cell Logic+, Class II A2 with Scope-Ready, Service Fixture, Vacu-Pass and Base Stand

 Scope-Ready A2 Cell Logic+ with base stand

Catalog Number: 332491170

  • Base Stand: Included
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Microscope-Compatible, Tube & Cable Pass-Through
  • Nominal Width: 4'
  • Power Cord & Plug: India, 230 volts
  • Sash Opening: 9"

5' Purifier Horizontal Clean Bench with UV Light

 5' Purifier Horizontal Clean Bench with UV Light

Catalog Number: 3250022

  • Built-in Options: UV light, UV screen
  • Laminar Flow: Horizontal
  • Nominal Width: 5'
  • Region: U.S. and Canada
  • Power Cord & Plug: North America, 230 volts

6' Protector Echo Filtered Benchtop Hood, side windows 115V

 6' Protector Echo Filtered Benchtop Hood, side windows 115V

Catalog Number: 181610001

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Benchtop

6' Protector Pass-Through Laboratory Hood, right window, 115V

 6' Protector Pass-Through Laboratory Hood, right window, 115V

Catalog Number: 113608000

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

6' Protector XL Benchtop Laboratory Hood, 24" interior depth

 Protector XL Hood Line Art

Catalog Number: 111600000

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Exterior Depth: 31.7" (80.5 cm)
  • Style: Benchtop

6' Purifier Cell Logic+, Class II B2 with Service Fixtures, Scope-Ready and Vacu-Pass Portal

 6' Purifier Cell Logic+, Class II B2 with Service Fixtures, Scope-Ready and Vacu-Pass Portal

Catalog Number: 333681000

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: U.S. and Canada
  • Built In Options: Hose Tip Valve(s), Microscope-Compatible, Tube & Cable Pass-Through
  • Nominal Width: 6'
  • Power Cord & Plug: North America, 115 volts, 20 amps
  • Sash Opening: 8"

6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixtures, Vacu-Pass Portal and Base Stand

 6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixtures, Vacu-Pass Portal and Base Stand

Catalog Number: 303681140

  • Base Stand: Included
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 6'
  • Power Cord & Plug: China/Australia, 230 volts
  • Sash Opening: 8"

6' XPert Balance Enclosure with Guardian Jr. Airflow Monitor

 6' XPert Balance Enclosure with Guardian Jr. Airflow Monitor

Catalog Number: 3971621

  • Region: International
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: No

6' XPert Filtered Balance Station, Deep

 6' XPert Filtered Balance Station, Deep

Catalog Number: 3946640

  • Region: International
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: Yes

6' XPert Filtered Balance System, Deep

 6' XPert Filtered Balance System, Deep

Catalog Number: 3950640

  • Region: International
  • Blower Requirements: Contains built-in blower and exhaust HEPA filter
  • Type: Balance Enclosure
  • Width: 6'
  • With Built-In HEPA Filtration: Yes

8' Protector Echo Filtered Floor-Mounted Fume Hood, 115V, 43.7" deep

 8' Protector Echo Filtered Floor-Mounted Fume Hood, 115V

Catalog Number: 183827000

  • Nominal Width: 8'
  • Sash Movement Direction: Vertical Rising
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Exterior Depth: 43.7" (111.0 cm)
  • Style: Floor-Mounted

3' Purifier Logic+ Class II A2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixture, Vacu-Pass Portal and Base Stand

 Logic Plus A2 with stand 800

Catalog Number: 302381110

  • Base Stand: Included
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: U.S. and Canada
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 3'
  • Power Cord & Plug: North America, 230 volts
  • Sash Opening: 8"

4' PuriCare Procedure Station with 10" sash opening

 4'  PuriCare Procedure Station with 10" sash opening

Catalog Number: 312410050

  • Region: International
  • Built-In Options: None
  • Light Fixtures: Fluorescent
  • Nominal Exterior Width: 4' (122 cm)
  • Power Cord & Plug: British (UK), 230 volts
  • Primary Application: Special procedures such as anesthesia delivery
  • Service Fixtures: No
  • Working Sash Height: 10" (25 cm)

4' Purifier Axiom C1 Biological Safety Cabinet, 230V UK (EN)

 4' Purifier Axiom C1 Biological Safety Cabinet, 230V UK (EN)

Catalog Number: 304480060

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type C1 Biosafety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Nominal Width: 4'
  • Power Cord & Plug: British (UK, EN Compliant), 230 volts
  • Sash Opening: 8"

4' Purifier Cell Logic+, Class II A2 with Service Fixture, Scope-Ready and Vacu-Pass Portal

 Cell Logic Plus A2 without stand Scope-Ready

Catalog Number: 332491000

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: U.S. and Canada
  • Built In Options: Hose Tip Valve(s), Microscope-Compatible, Tube & Cable Pass-Through
  • Nominal Width: 4'
  • Power Cord & Plug: North America, 115 volts, 15 amps
  • Sash Opening: 9"

5' Purifier Horizontal Clean Bench, Deep

 5' Purifier Horizontal Clean Bench, Deep

Catalog Number: 3250001

  • Laminar Flow: Horizontal
  • Nominal Width: 5'
  • Region: U.S. and Canada
  • Power Cord & Plug: North America, 115 volts, 15 amps

6' Protector Echo Filtered Benchtop Hood, side windows 115V

 6' Protector Echo Filtered Benchtop Hood, side windows 115V

Catalog Number: 181610002

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Electrical Duplexes: 1
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Benchtop

6' Protector Pass-Through Laboratory Hood, right window, 230V

 6' Protector Pass-Through Laboratory Hood, right window, 230V

Catalog Number: 113608020

  • Nominal Width: 6'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop