HomeProductsVentilated Enclosures & Exhausters

Ventilated Enclosures & Exhausters

Narrow results

‹ First  « Previous 16 1718 19 20 Next »  Last ›

Showing 681 - 720 of 2398 Results

Explosion Proof Coated Steel Blowers

 Coated Steel Blower

Catalog Number: 7069500

  • Product Subcategory: Coated Steel Blowers
  • Motor Type: Traditional Belt Driven Motor
  • CFM: Between 1000 and 2000
  • Explosion-Proof: Yes
  • Hood Application: Low to moderately corrosive
  • HP: 1
  • Inlet/Outlet: 12.25" Inlet, 7.0" d x 13.50" w Outlet

Fiberglass Blower

 Fiberglass Blower

Catalog Number: 7181200

  • Product Subcategory: Fiberglass Blowers
  • Motor Type: Traditional Belt Driven Motor
  • CFM: Between 1000 and 2000
  • Explosion-Proof: No
  • Hood Application: Moderate to highly corrosive
  • HP: 1/2
  • Inlet/Outlet: 12.38" Inlet, 12.75" Outlet

3' Purifier Cell Logic+, Class II A2 with Temp-Zone, Scope-Ready, Service Fixture, Vacu-Pass Portal and Base Stand

 Scope-Ready A2 Cell Logic+ with base stand

Catalog Number: 342391140

  • Base Stand: Included
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Microscope-Compatible, Temperature-Controlled Work Surface Area, Tube & Cable Pass-Through
  • Nominal Width: 3'
  • Power Cord & Plug: China/Australia, 230 volts
  • Sash Opening: 9"

3' Purifier Horizontal Clean Bench, Deep, with UV Light

 4 ft Purifier Horizontal Clean Bench

Catalog Number: 3889729

  • Built-in Options: UV light, UV screen
  • Laminar Flow: Horizontal
  • Nominal Width: 3'
  • Region: International
  • Power Cord & Plug: Schuko, 230 volts

3' Purifier Logic+ Class II A2 Biological Safety Cabinet with 10" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

 3' Purifier Logic+ Class II A2 Biological Safety Cabinet with 10" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

Catalog Number: 302311010

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: U.S. and Canada
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 3'
  • Power Cord & Plug: North America, 230 volts
  • Sash Opening: 10"

3' XPert Balance Enclosure, Tall with Guardian Jr. Airflow Monitor

 3' XPert Balance Enclosure, Tall with Guardian Jr. Airflow Monitor

Catalog Number: 3930331

  • Region: U.S. and Canada
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 3'
  • With Built-In HEPA Filtration: No

4' Protector Airo Filtered Benchtop Hood, 230V, 2 Fixtures

 4' Protector Airo Filtered Benchtop Hood, 230V, 2 Fixtures

Catalog Number: 184410021

  • Nominal Width: 4'
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Electrical Duplexes: 2
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Benchtop

4' Protector Pass-Through Laboratory Hood, left window, 230V

 4' Protector Pass-Through Laboratory Hood, left window, 230V

Catalog Number: 113407020

  • Nominal Width: 4'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

4' Protector XL Benchtop Laboratory Hood with 2 services fixtures and 1 electrical duplex, 24" interior depth

 Protector XL Hood Line Art

Catalog Number: 111400002

  • Nominal Width: 4'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Electrical Duplexes: 1
  • Service Fixtures: 2
  • Style: Benchtop

4' Purifier Axiom C1 Biological Safety Cabinet, 230V China with Base Stand

 4' Purifier Axiom C1 Biological Safety Cabinet, 230V China with Base Stand

Catalog Number: 304480140

  • Base Stand: Included
  • Product Subcategory: Class II, Type C1 Biosafety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Nominal Width: 4'
  • Power Cord & Plug: China/Australia, 230 volts
  • Sash Opening: 8"

4' Purifier Cell Logic+, Class II B2 with Temp-Zone, Service Fixture, UV Light, Vacu-Pass Portal and Base Stand

 4' Purifier Cell Logic+, Class II B2 with Temp-Zone, Service Fixture, UV Light, Vacu-Pass Portal and Base Stand

Catalog Number: 343481140

  • Base Stand: Included
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Temperature-Controlled Work Surface Area, Tube & Cable Pass-Through, UV Light
  • Power Cord & Plug: China/Australia, 230 volts
  • Sash Opening: 8"

4' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

 4' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

Catalog Number: 303481050

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 4'
  • Power Cord & Plug: British (UK), 230 volts
  • Sash Opening: 8"

4' Purifier Vertical Clean Bench with Airflow Monitor

 2' Vertical Clean Bench without UV

Catalog Number: 3970403

  • Built-in Options: Airflow monitor
  • Laminar Flow: Vertical
  • Nominal Width: 4'
  • Region: U.S. and Canada
  • Power Cord & Plug: North America, 115 volts, 15 amps

4' XPert Filtered Balance Station, Tall

 4' XPert Filtered Balance Station, Tall

Catalog Number: 3940460

  • Region: U.S. and Canada
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 4'
  • With Built-In HEPA Filtration: Yes

4' XPert Filtered Balance System, Tall

 4' XPert Filtered Balance System, Tall

Catalog Number: 3950460

  • Region: U.S. and Canada
  • Blower Requirements: Contains built-in blower and exhaust HEPA filter
  • Type: Balance Enclosure
  • Width: 4'
  • With Built-In HEPA Filtration: Yes

5' Paramount Ductless Enclosure, Tall & Deep

 5' Paramount Ductless Enclosure, Tall & Deep

Catalog Number: 6963503

  • Region: U.S. and Canada
  • Filters Available: Acid-Sulfur, Ammonia-Amine, Formaldehyde, HEPA, Mixed Bed, Organic Vapor, Radioisotope
  • Interior Height: 35.0"
  • Nominal Width: 5'
  • Outside ducting: Optional

5' Protector Echo Filtered Benchtop Hood, back and side windows 115V

 5' Protector Echo Filtered Benchtop Hood, back and side windows 115V

Catalog Number: 182510000

  • Nominal Width: 5'
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Exterior Depth: 37.7" (95.8 cm)
  • Style: Benchtop

5' Protector Echo Filtered Floor-Mounted Fume Hood, 115V, 37.7" deep, 2 Fixtures, 1 Receptacle

 5' Protector Echo Filtered Floor-Mounted Fume Hood, 115V, 2 Fixtures, 1 Receptacle

Catalog Number: 183517002

  • Nominal Width: 5'
  • Sash Movement Direction: Vertical Rising
  • Region: U.S. and Canada, International
  • Blower Requirements: Integral blower included
  • Electrical Duplexes: 1
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Floor-Mounted

5' Protector Premier Laboratory Hood with 2 service fixtures and 1 electrical duplex

 5' Protector Premier COB cropped

Catalog Number: 100500002

  • Nominal Width: 5'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Electrical Duplexes: 1
  • Service Fixtures: 2
  • Style: Benchtop

5' Protector Stainless Steel Perchloric Acid Laboratory Hood, 230V

 5' Protector Stainless Steel Perchloric Acid Laboratory Hood, 230V

Catalog Number: 130500020

  • Nominal Width: 5'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

5' Protector Stainless Steel Radioisotope Laboratory Hood, 230V

 5' Protector Stainless Steel Radioisotope Laboratory Hood, 230V

Catalog Number: 120500020

  • Nominal Width: 5'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

5' RXPert Double Filtered System, Tall

 5' RXPert Double Filtered System, Tall

Catalog Number: 3971585

  • Work Surface Included: None
  • Region: U.S. and Canada
  • Blower Requirements: Contains built-in blower and exhaust HEPA filter
  • Type: Balance Enclosure
  • Width: 5'
  • With Built-In HEPA Filtration: Yes

5' RXPert System, Tall

 5' RXPert System, Tall

Catalog Number: 3971575

  • Work Surface Included: None
  • Region: U.S. and Canada
  • Blower Requirements: Contains built-in blower and exhaust HEPA filter
  • Type: Balance Enclosure
  • Width: 5'
  • With Built-In HEPA Filtration: Yes

5' XPert Nano Enclosure with Ionizer

 5' XPert Nano Enclosure with Ionizer

Catalog Number: 3887561

  • Region: U.S. and Canada
  • Built-In Ionizer: Yes
  • Filter Type: ULPA
  • Lighting: Front-mounted fluorescent lamp
  • Width: 5'

8' Protector PVC Acid Digestion Laboratory Hood, 115V

 8' Protector PVC Acid Digestion Laboratory Hood, 115V

Catalog Number: 141810000

  • Nominal Width: 8'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

8' Protector PVC Perchloric Acid Laboratory Hood, 115V

 8' Protector PVC Perchloric Acid Laboratory Hood, 115V

Catalog Number: 140810000

  • Nominal Width: 8'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

8' Protector XStream Laboratory Hood with 2 service fixtures

 6' XStream Hood

Catalog Number: 110810021

  • Nominal Width: 8'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Benchtop

Basic 70 Laboratory Hood

 Basic 70 with model

Catalog Number: 2246501

  • Nominal Width: 6'
  • Region: International
  • Blower Requirements: Integral explosion-proof blower included
  • Explosion-Proof: Explosion-Proof Model
  • Style: Benchtop

Explosion Proof Coated Steel Blowers

 Coated Steel Blower

Catalog Number: 7069700

  • Product Subcategory: Coated Steel Blowers
  • Motor Type: Traditional Belt Driven Motor
  • CFM: Between 2000 and 3000
  • Explosion-Proof: Yes
  • Hood Application: Low to moderately corrosive
  • HP: 1 1/2
  • Inlet/Outlet: 12.25" Inlet, 7.0" d x 13.50" w Outlet

Fiberglass Blower

 Fiberglass Blower

Catalog Number: 7181400

  • Product Subcategory: Fiberglass Blowers
  • Motor Type: Traditional Belt Driven Motor
  • CFM: Between 1000 and 2000
  • Explosion-Proof: No
  • Hood Application: Moderate to highly corrosive
  • HP: 3/4
  • Inlet/Outlet: 12.38" Inlet, 12.75" Outlet

3' Purifier Cell Logic+, Class II A2 with Temp-Zone, Scope-Ready, Service Fixture, Vacu-Pass Portal and Base Stand

 Scope-Ready A2 Cell Logic+ with base stand

Catalog Number: 342391110

  • Base Stand: Included
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: U.S. and Canada
  • Built In Options: Hose Tip Valve(s), Microscope-Compatible, Temperature-Controlled Work Surface Area, Tube & Cable Pass-Through
  • Nominal Width: 3'
  • Power Cord & Plug: North America, 230 volts
  • Sash Opening: 9"

3' Purifier Horizontal Clean Bench, Deep, with UV Light

 4 ft Purifier Horizontal Clean Bench

Catalog Number: 3889721

  • Built-in Options: UV light, UV screen
  • Laminar Flow: Horizontal
  • Nominal Width: 3'
  • Region: U.S. and Canada
  • Power Cord & Plug: North America, 115 volts, 15 amps

3' Purifier Logic+ Class II A2 Biological Safety Cabinet with 10" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

 3' Purifier Logic+ Class II A2 Biological Safety Cabinet with 10" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

Catalog Number: 302311070

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 3'
  • Power Cord & Plug: India, 230 volts
  • Sash Opening: 10"

3' XPert Balance Enclosure, Tall with Guardian Jr. Airflow Monitor

 3' XPert Balance Enclosure, Tall with Guardian Jr. Airflow Monitor

Catalog Number: 3930341

  • Region: U.S. and Canada
  • Blower Requirements: Remote blower or FilterMate Portable Exhauster(s) and filters required
  • Type: Balance Enclosure
  • Width: 3'
  • With Built-In HEPA Filtration: No

4' Protector Pass-Through Laboratory Hood, right window, 115V

 4' Protector Pass-Through Laboratory Hood, right window, 115V

Catalog Number: 113408000

  • Nominal Width: 4'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Style: Benchtop

4' Protector XL Benchtop Laboratory Hood with 2 services fixtures and 1 electrical duplex, 30" interior depth

 Protector XL Hood Line Art

Catalog Number: 111410002

  • Nominal Width: 4'
  • Region: U.S. and Canada, International
  • Blower Requirements: Remote blower required
  • Electrical Duplexes: 1
  • Exterior Depth: 37.7" (95.8 cm)
  • Service Fixtures: 2
  • Style: Benchtop

4' Purifier Axiom C1 Biological Safety Cabinet, 230V China with Base Stand

 4' Purifier Axiom C1 Biological Safety Cabinet, 230V China with Base Stand

Catalog Number: 304410140

  • Base Stand: Included
  • Product Subcategory: Class II, Type C1 Biosafety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Nominal Width: 4'
  • Power Cord & Plug: China/Australia, 230 volts
  • Sash Opening: 10"

4' Purifier Cell Logic+, Class II B2 with Temp-Zone, Service Fixture, UV Light, Vacu-Pass Portal and Base Stand

 4' Purifier Cell Logic+, Class II B2 with Temp-Zone, Service Fixture, UV Light, Vacu-Pass Portal and Base Stand

Catalog Number: 343481110

  • Base Stand: Included
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: U.S. and Canada
  • Built In Options: Hose Tip Valve(s), Temperature-Controlled Work Surface Area, Tube & Cable Pass-Through, UV Light
  • Power Cord & Plug: North America, 230 volts
  • Sash Opening: 8"

4' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

 4' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8" sash opening, UV Light, Service Fixture and Vacu-Pass Portal

Catalog Number: 303481020

  • Base Stand: Required (not included)
  • Product Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets
  • Protection Type: Product and Personnel
  • Region: International
  • Built In Options: Hose Tip Valve(s), Tube & Cable Pass-Through, UV Light
  • Nominal Width: 4'
  • Power Cord & Plug: 100 volts, 15 amps
  • Sash Opening: 8"

4' Purifier Vertical Clean Bench with Airflow Monitor

 2' Vertical Clean Bench without UV

Catalog Number: 3970423

  • Built-in Options: Airflow monitor
  • Laminar Flow: Vertical
  • Nominal Width: 4'
  • Region: International
  • Power Cord & Plug: 230 volts, 10 amps, no plug