|| Products  >> Freeze Dry Systems  >> FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems

FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems

The FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems have ice holding capacity for light to moderate loads and have dual refrigeration systems for samples with very low eutectic points including ones containing small amounts of methanol or ethanol. They have a compact benchtop design and include a 12-Port Drying Chamber. A vacuum pump and sample containers, such as flasks, are the only additional components necessary for a complete system.

Filter Reminder Service

FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems

Catalog # Summary
7382020 115 volt, 20 A Plug Type, Domestic Electrical
7382030 Schuko Plug Type, International Electrical
7382032 British (UK) Plug Type, International Electrical
7382034 China/Australia Plug Type, International Electrical
7382040 North America, 230 volt Plug Type, Domestic Electrical

FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems with Teflon-Coated Collector

Catalog # Summary
7382021 115 volt, 20 A Plug Type, Domestic Electrical
7382031 Schuko Plug Type, International Electrical
7382033 British (UK) Plug Type, International Electrical
7382035 China/Australia Plug Type, International Electrical
7382041 North America, 230 volt Plug Type, Domestic Electrical
A Guide to Freeze Drying for the Laboratory Industry service publication which provides background information on the principles of freeze drying.
download PDF (Login Required)
Recommended by Labconco!
FreeZone Freeze Dry Systems, Tray Dryers and Benchtop Shell Freezers Ordering Information Brochure Provides ordering information on the full line of FreeZone Freeze Dry Systems, Tray Dryers and Benchtop Shell Freezers, including models with Schuko, British (UK) and China/Australia plugs.
download PDF (Login Required)
FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems Contains description and information on FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems
download PDF (Login Required)
FreeZone -105°C and FreeZone Plus 4.5 Liter Cascade Freeze Dry Systems User's Manual Manual for FreeZone -105°C 4.5 Liter Benchtop Freeze Dry Systems and FreeZone Plus 4.5 Liter Cascade Freeze Dry Systems.
download PDF (Login Required)
Ethylene MSDS Material safety data sheet for refrigerant used in FreeZone -105°C Freeze Dry Systems.
download PDF (Login Required)
Interactive Freeze Dry System Selection Guide This interactive PDF allows you to find the perfect freeze dry system by allowing you to customize criteria such as size, collector temperature and style.
download PDF
Methodologies using the Freeze Dryer Approximate Freeze Drying Times, Procedure for Freeze Drying Fish Samples for Volatile Substances Using a 4.5 Liter Freeze Dry System, Extraction and Analytical Method for "Microcystin LR" in Cyanobacteria Samples, General Freeze Dry Application for Snake Venom and Other Small Volume Samples of 0.4 ml or Less, Freeze Drying Fungi, General Freeze Dry Application for Monitoring Soil Samples, Freeze Dry Applications for Monitoring Anti-Cancer Drugs and Freeze Drying Mango Powder.
download PDF (Login Required)
Concentration of Solutes: Options for the Removal of Solvents from Samples Briefly discusses the various options for removing solvents including evaporation, vacuum concentration, lyophilization, reverse extraction, dialysis and precipitation.
download PDF (Login Required)
download HTML
With so many freeze dryers, how do you choose? Here are some pointers.
download PDF (Login Required)
download HTML (Login Required)
How to Build a Freeze Dry System
download HTML
download PDF (Login Required)
How long will it take to freeze dry my samples?
download HTML
download PDF (Login Required)
Lyophilization, Concentration or Evaporation?
download PDF (Login Required)
Using Methanol as an alternative to Acetonitrile in lyophilization - what's hot, what's not.
download PDF (Login Required)
Application of Glutathione in Protecting Freeze Dried Biomolecules Article describes how glutathione prevents oxidation until a freeze dried sample is reconstituted.
download PDF (Login Required)
download HTML (Login Required)

Compliance

• UL Standard 61010A-1 (60 Hz models)
• CAN/CSA C22.2 No. 1010.1 (60 Hz models)
• CE Conformity marking (230 volts, 50 Hz models)

Features

• Dual 1/3 hp HCFC/CFC-free refrigeration systems to cool collector to -105¡C (-157¡F)
• LCD that displays system operating parameters, set-up parameters and alarm messages
• Red alarm light that flashes and beeper that sounds to indicate that an abnormal system event has occurred, including: power failure, improper line voltage supply, collector temperature rise above -60¡C, service vacuum pump (after 100 hours of vacuum use), and moisture in collector.
• Moisture sensor that prevents refrigeration or vacuum start-up when moisture is detected in the collector chamber area.
• Vacuum break valve that bleeds air into the system when power to the freeze dryer or vacuum pump is shut off.
• Upright stainless steel collector coil that holds 4.5 liters of ice before defrosting
12-Port Drying Chamber 7522800 included
• LED vacuum and temperature ÒwavesÓ for at-a-glance display of relative system vacuum and collector temperature.
• Vacuum control valve that maintains setpoint vacuum level.
• Rear-mounted RS-232 port to transmit data to a user-supplied computer. Transmission intervals may be user-configured for 10, 30, 60, 300 or 600 seconds.
• Automatic start-up switch for collector cool-down and vacuum pull-down with manual override switches.
• Side-mounted, retractable, 9Ó collector drain hose.
• Brushed stainless steel and glacier white, epoxy-coated steel exterior with blue accents
• Clear acrylic lid, _Ó thick, with 3Ó diameter port for connection of drying chamber (included).
• Side-mounted power switch and rear-mounted electrical receptacle (for vacuum pump connection)
• 3/4Ó OD vacuum connection, three feet of _Ó ID vacuum hose and two clamps

Options

• Teflon-coated collector coil and chamber for processes involving corrosive compounds
• Domestic or international electrical configuration

Required Accessories

Vacuum Pump with a displacement of at least 86 liters per minute, 0.002 mBar ultimate pressure, 15 amp NEMA 5-15P plug (115 volt models) or reverse IEC plug (230 volt models) and fitting suitable for _Ó ID vacuum hose.
Freeze Dry glassware