|| Products  >> HEPA Filtered Biological Safety Cabinets, Enclosures and Clean Benches  >> Class II, Type A2 Purifier Cell Logic Biological Safety Cabinets

Class II, Type A2 Purifier Cell Logic Biological Safety Cabinets

Purifier Cell Logic Class II, Type A2 Biosafety Cabinets are specially designed with cell researchers in mind, while also providing protection from hazardous particulates such as agents that require Biosafety Level 1,2 or 3 containment.

Purifier Cell Logic Biosafety Cabinets featuring the Scope-Ready package option allow a user-supplied microscope to be integrated into the cabinet. The Pure-Vu Seal is a flexible, chemical-resistant clear eyepiece seal that prevents contaminants from escaping while also providing ergonomic visibility into the cabinet. Also part of the Scope-Ready package option is the Stand-Still Isolation Platform, which supports the microscope on the cabinet's work surface and reduces vibration by up to 300%.

Purifier Cell Logic Biosafety Cabinets featuring the Temp-Zone package option include a temperature-controlled area on the work surface, where warm or chilled samples may be transferred and kept at an optimum and uniform temperature. Easy-Clean Prop Rods allow for hands-free elevation of the work surface for ease of cleaning and access to the channels and drain.

These biohazard laminar flow cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-ducted, these biological safety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological

Filter Reminder Service Filter Reminder Service

Get an email reminder to check or change your filters! Set up reminder now.

3' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready & Temp-Zone

Catalog # Summary
3430930 Domestic Electrical Requirements, One, Scope-Ready, Temp-Zone, 1 service fixture
3430932 International Electrical Requirements, 100 volts, 15 amps, One, Scope-Ready, Temp-Zone, 1 service fixture
3430934 International Electrical Requirements, British (UK), One, Scope-Ready, Temp-Zone, 1 service fixture
3430936 International Electrical Requirements, Schuko, One, Scope-Ready, Temp-Zone, 1 service fixture
3430938 International Electrical Requirements, China/Australia, One, Scope-Ready, Temp-Zone, 1 service fixture
3430940 Domestic Electrical Requirements, North America, 230 volts, One, Scope-Ready, Temp-Zone, 1 service fixture

3' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready

Catalog # Summary
3430960 Domestic Electrical Requirements, One, Scope-Ready, 1 service fixture
3430962 International Electrical Requirements, 100 volts, 15 amps, One, Scope-Ready, 1 service fixture
3430964 International Electrical Requirements, British (UK), One, Scope-Ready, 1 service fixture
3430966 International Electrical Requirements, Schuko, One, Scope-Ready, 1 service fixture
3430968 International Electrical Requirements, China/Australia, One, Scope-Ready, 1 service fixture
3430970 Domestic Electrical Requirements, North America, 230 volts, One, Scope-Ready, 1 service fixture

3' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Temp-Zone

Catalog # Summary
3430980 Domestic Electrical Requirements, One, Temp-Zone, 1 service fixture
3430981 Domestic Electrical Requirements, One, Temp-Zone, UV Light, 1 service fixture
3430982 International Electrical Requirements, 100 volts, 15 amps, One, Temp-Zone, 1 service fixture
3430983 International Electrical Requirements, 100 volts, 15 amps, One, Temp-Zone, UV Light, 1 service fixture
3430984 International Electrical Requirements, British (UK), One, Temp-Zone, 1 service fixture
3430985 International Electrical Requirements, British (UK), One, Temp-Zone, UV Light, 1 service fixture
3430986 International Electrical Requirements, Schuko, One, Temp-Zone, 1 service fixture
3430987 International Electrical Requirements, Schuko, One, Temp-Zone, UV Light, 1 service fixture
3430988 International Electrical Requirements, China/Australia, One, Temp-Zone, 1 service fixture
3430989 International Electrical Requirements, China/Australia, One, Temp-Zone, UV Light, 1 service fixture
3430990 Domestic Electrical Requirements, North America, 230 volts, One, Temp-Zone, 1 service fixture
3430991 Domestic Electrical Requirements, North America, 230 volts, One, Temp-Zone, UV Light, 1 service fixture

4' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready & Temp-Zone

Catalog # Summary
3440930 Domestic Electrical Requirements, One, Scope-Ready, Temp-Zone, 1 service fixture
3440932 International Electrical Requirements, 100 volts, 15 amps, One, Scope-Ready, Temp-Zone, 1 service fixture
3440934 International Electrical Requirements, British (UK), One, Scope-Ready, Temp-Zone, 1 service fixture
3440936 International Electrical Requirements, Schuko, One, Scope-Ready, Temp-Zone, 1 service fixture
3440938 International Electrical Requirements, China/Australia, One, Scope-Ready, Temp-Zone, 1 service fixture
3440940 Domestic Electrical Requirements, North America, 230 volts, One, Scope-Ready, Temp-Zone, 1 service fixture
3440942 International Electrical Requirements, Schuko, One, Scope-Ready, Temp-Zone, 1 service fixture with solenoid valve

4' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready

Catalog # Summary
3440960 Domestic Electrical Requirements, One, Scope-Ready, 1 service fixture
3440962 International Electrical Requirements, 100 volts, 15 amps, One, Scope-Ready, 1 service fixture
3440964 International Electrical Requirements, British (UK), One, Scope-Ready, 1 service fixture
3440966 International Electrical Requirements, Schuko, One, Scope-Ready, 1 service fixture
3440968 International Electrical Requirements, China/Australia, One, Scope-Ready, 1 service fixture
3440970 Domestic Electrical Requirements, North America, 230 volts, One, Scope-Ready, 1 service fixture
3440972 International Electrical Requirements, Schuko, One, Scope-Ready, 1 service fixture with solenoid valve

4' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Temp-Zone

Catalog # Summary
3440980 Domestic Electrical Requirements, One, Temp-Zone, 1 service fixture
3440981 Domestic Electrical Requirements, One, Temp-Zone, UV Light, 1 service fixture
3440982 International Electrical Requirements, 100 volts, 15 amps, One, Temp-Zone, 1 service fixture
3440983 International Electrical Requirements, 100 volts, 15 amps, One, Temp-Zone, UV Light, 1 service fixture
3440984 International Electrical Requirements, British (UK), One, Temp-Zone, 1 service fixture
3440985 International Electrical Requirements, British (UK), One, Temp-Zone, UV Light, 1 service fixture
3440986 International Electrical Requirements, Schuko, One, Temp-Zone, 1 service fixture
3440987 International Electrical Requirements, Schuko, One, Temp-Zone, UV Light, 1 service fixture
3440988 International Electrical Requirements, China/Australia, One, Temp-Zone, 1 service fixture
3440989 International Electrical Requirements, China/Australia, One, Temp-Zone, UV Light, 1 service fixture
3440990 Domestic Electrical Requirements, North America, 230 volts, One, Temp-Zone, 1 service fixture
3440991 Domestic Electrical Requirements, North America, 230 volts, One, Temp-Zone, UV Light, 1 service fixture
3440992 International Electrical Requirements, Schuko, One, Temp-Zone, UV Light, 1 service fixture with solenoid valve
3440993 International Electrical Requirements, Schuko, One, Temp-Zone, UV Light, 1 service fixture with solenoid valve

5' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready & Temp-Zone

Catalog # Summary
3450930 Domestic Electrical Requirements, One, Scope-Ready, Temp-Zone, 1 service fixture
3450932 International Electrical Requirements, 100 volts, 15 amps, One, Scope-Ready, Temp-Zone, 1 service fixture
3450934 International Electrical Requirements, British (UK), One, Scope-Ready, Temp-Zone, 1 service fixture
3450936 International Electrical Requirements, Schuko, One, Scope-Ready, Temp-Zone, 1 service fixture
3450938 International Electrical Requirements, China/Australia, One, Scope-Ready, Temp-Zone, 1 service fixture
3450940 Domestic Electrical Requirements, North America, 230 volts, One, Scope-Ready, Temp-Zone, 1 service fixture

5' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready

Catalog # Summary
3450960 Domestic Electrical Requirements, One, Scope-Ready, 1 service fixture
3450962 International Electrical Requirements, 100 volts, 15 amps, One, Scope-Ready, 1 service fixture
3450964 International Electrical Requirements, British (UK), One, Scope-Ready, 1 service fixture
3450966 International Electrical Requirements, Schuko, One, Scope-Ready, 1 service fixture
3450968 International Electrical Requirements, China/Australia, One, Scope-Ready, 1 service fixture
3450970 Domestic Electrical Requirements, North America, 230 volts, One, Scope-Ready, 1 service fixture

5' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Temp-Zone

Catalog # Summary
3450980 Domestic Electrical Requirements, One, Temp-Zone, 1 service fixture
3450981 Domestic Electrical Requirements, One, Temp-Zone, UV Light, 1 service fixture
3450982 International Electrical Requirements, 100 volts, 15 amps, One, Temp-Zone, 1 service fixture
3450983 International Electrical Requirements, 100 volts, 15 amps, One, Temp-Zone, UV Light, 1 service fixture
3450984 International Electrical Requirements, British (UK), One, Temp-Zone, 1 service fixture
3450985 International Electrical Requirements, British (UK), One, Temp-Zone, UV Light, 1 service fixture
3450986 International Electrical Requirements, Schuko, One, Temp-Zone, 1 service fixture
3450987 International Electrical Requirements, Schuko, One, Temp-Zone, UV Light, 1 service fixture
3450988 International Electrical Requirements, China/Australia, One, Temp-Zone, 1 service fixture
3450989 International Electrical Requirements, China/Australia, One, Temp-Zone, UV Light, 1 service fixture
3450990 Domestic Electrical Requirements, North America, 230 volts, One, Temp-Zone, 1 service fixture
3450991 Domestic Electrical Requirements, North America, 230 volts, One, Temp-Zone, UV Light, 1 service fixture

6' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready & Temp-Zone

Catalog # Summary
3460930 6' Nominal Width, Domestic Electrical Requirements, Two, Scope-Ready, Temp-Zone, 2 service fixtures
3460932 6' Nominal Width, International Electrical Requirements, 100 volts, 15 amps, Two, Scope-Ready, Temp-Zone, 2 service fixtures
3460934 6' Nominal Width, International Electrical Requirements, British (UK), Two, Scope-Ready, Temp-Zone, 2 service fixtures
3460936 6' Nominal Width, International Electrical Requirements, Schuko, Two, Scope-Ready, Temp-Zone, 2 service fixtures
3460938 6' Nominal Width, International Electrical Requirements, China/Australia, Two, Scope-Ready, Temp-Zone, 2 service fixtures
3460940 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two, Scope-Ready, Temp-Zone, 2 service fixtures

6' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Scope-Ready

Catalog # Summary
3460960 6' Nominal Width, Domestic Electrical Requirements, Two, Scope-Ready, 2 service fixtures
3460962 6' Nominal Width, International Electrical Requirements, 100 volts, 15 amps, Two, Scope-Ready, 2 service fixtures
3460964 6' Nominal Width, International Electrical Requirements, British (UK), Two, Scope-Ready, 2 service fixtures
3460966 6' Nominal Width, International Electrical Requirements, Schuko, Two, Scope-Ready, 2 service fixtures
3460968 6' Nominal Width, International Electrical Requirements, China/Australia, Two, Scope-Ready, 2 service fixtures
3460970 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two, Scope-Ready, 2 service fixtures

6' Purifier Cell Logic Class II, Type A2 Biosafety Cabinet - Temp-Zone

Catalog # Summary
3460980 6' Nominal Width, Domestic Electrical Requirements, Two, Temp-Zone, 2 service fixtures
3460981 6' Nominal Width, Domestic Electrical Requirements, Two, Temp-Zone, UV Light, 2 service fixtures
3460982 6' Nominal Width, International Electrical Requirements, 100 volts, 15 amps, Two, Temp-Zone, 2 service fixtures
3460983 6' Nominal Width, International Electrical Requirements, 100 volts, 15 amps, Two, Temp-Zone, UV Light, 2 service fixtures
3460984 6' Nominal Width, International Electrical Requirements, British (UK), Two, Temp-Zone, 2 service fixtures
3460985 6' Nominal Width, International Electrical Requirements, British (UK), Two, Temp-Zone, UV Light, 2 service fixtures
3460986 6' Nominal Width, International Electrical Requirements, Schuko, Two, Temp-Zone, 2 service fixtures
3460987 6' Nominal Width, International Electrical Requirements, Schuko, Two, Temp-Zone, UV Light, 2 service fixtures
3460988 6' Nominal Width, International Electrical Requirements, China/Australia, Two, Temp-Zone, 2 service fixtures
3460989 6' Nominal Width, International Electrical Requirements, China/Australia, Two, Temp-Zone, UV Light, 2 service fixtures
3460990 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two, Temp-Zone, 2 service fixtures
3460991 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two, Temp-Zone, UV Light, 2 service fixtures
Purifier Safety Enclosures, Clean Benches & Non-Ventilated Enclosures Catalog Contains information on Purifier Class I and HEPA-Filtered Enclosures, Purifier Horizontal and Vertical Clean Benches, Purifier Filtered PCR Enclosures, and Purifier Non-Ventilated PCR and Tissue Culture Enclosures.
download PDF (Login Required)
Purifier Logic Biosafety Cabinets Catalog Contains information on the Purifier Logic Class II, Type A2 and B2 Biosafety Cabinets and accessories.
download PDF (Login Required)
Personnel and Product Protection: A Guide To Biosafety Enclosures Industry service publication provides helpful information on choosing the right biological safety cabinet for your application. Types of cabinets and selection considerations are discussed.
download PDF (Login Required)
Recommended by Labconco!
Purifier Cell Logic Biological Safety Cabinets Manual For catalog numbers: 34309 Series, 34509 Series, 34409 Series, 34609 Series
download PDF (Login Required)
Purifier Logic Bag-In Bag-Out Assembly Instructions
Outlines the procedure for assembling the bag-in bag-out filter replacement system on a Purifier Logic Biosafety Cabinet or Purifier Cell Logic Biosafety Cabinet.
download PDF (Login Required)
Purifier Logic Unpacking Instructions Outlines the procedure for unpacking a Purifier Logic or Purifier Cell Logic Biosafety Cabinet.
download PDF (Login Required)
Biological Safety Cabinets & Enclosures Selection Guide

Selection guide presents a comparison of the features, available options and potential applications for Labconco''s range of Class II and Class I Biological Safety Cabinets & Enclosures.

download PDF (Login Required)
To B2 or not to B2 — A Biological Safety Cabinet Story
download HTML
download PDF (Login Required)
Logically Controlling Airflow: Advantages of the Logic ECM
download HTML
download PDF (Login Required)
New Purifier Cell Logic Biosafety Cabinets safely accommodate a microscope and keep samples at optimum temperature.
download PDF (Login Required)
download HTML (Login Required)
Are your cell culture samples in the ZONE?
download HTML
download PDF (Login Required)
Cell Logic: Identifying 'Non-traditional' Applications
download HTML
download PDF (Login Required)
The Advantages of Using an Electronically Commutated Motor (ECM) in Biosafety Cabinets This white paper explains the ECM motor in our Purifier Logic Biological Safety Cabinets and its advantages over PSC motors.
download PDF (Login Required)
Controlling Airflow in Class II Biosafety Cabinets This white paper reviews the current technologies used by various biosafety cabinet manufacturers to monitor and maintain proper airflows as HEPA filters load.
download PDF (Login Required)

Features

• Nominal inflow velocity of 105 fpm (0.5 m/sec)
• Nominal downflow velocity of 55 fpm (0.3 m/sec)
• Patent-pending design
• Interior-mounted, line-of-sight LCD information center with "Filter Life Remaining" bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20%, 10% and 0%
• Filter monitoring system consisting of an electronically commutated motor (ECM) that delivers a precise volume of air as required and automatically adjusts as filters load without relying on airflow sensors
• Smart-Start™ System that allows the user to program start up and shut down operations when the sash is raised or lowered
• Night-Smart™ System that idles the blower when the sash is fully closed
• Built-in interval or elapsed timer for experiment monitoring or UV light control (on models with UV light)
• Touchpad control on right-hand side post for manual activation of blower, light, timer, audible alarm mute and menu selection
• Radiused type 304 stainless steel interior and removable, seamless, dished work surface with lift out knobsService fixture (6' models have two) with ball-type valve
• Service fixture (two on 6’ models) with ball-type valve
• Epoxy-coated steel exterior
• Towel catch located under work surface
• Contain-Air™ Negative Pressure Channel
• Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
• Supply and exhaust 99.99% efficient HEPA filters
• Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption and stainless steel splash covers
• Fully-closing, clear 1/4" tempered safety glass sash with two sash handles; counterbalanced, anti-racking mechanism; and 10° slope
• 9.0” (23 cm) working sash opening height, 21.7” (54 cm) maximum sash opening height and 27.0” (69 cm) viewing height
• Curved stainless steel inlet grille with Reserve-Air™ Secondary Airflow Slots
• Bright, 90-100 foot-candle, glare-free fluorescent lighting located outside the contaminated work area
• Intrinsically safe negative pressure design
• Electronic security lock (optional activation) that requires code to operate the cabinet
• 10’ (3 m) power cord with plug
• Full three year warranty
• NSF-Compliant
• ETL listed (115 volt, 60 Hz models)
• CE conformity (230 volt, 50 Hz models)
• EN 12469 compliant (3440830 and 3440831 models)

Options

• 3’, 4’, 5’ and 6’ widths
• Scope-Ready package option with Pure-Vu Seal and Stand-Still Isolation Platform
• Temp-Zone package option with temperature controlled work surface and Easy-Clean prop rods
• International electrical configurations
• 99.999% ULPA filters. Contact Labconco for ordering information.