|| Products  >> HEPA Filtered Biological Safety Cabinets, Enclosures and Clean Benches  >> Class II, Type A2 Biological Safety Cabinets

Class II, Type A2 Biological Safety Cabinets

Purifier Logic Class II, Type A2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, carcinogens, allergens and additional substances that generate hazardous airborne particulates. All models are NSF-Listed.

During operation, room air is drawn into the inlet grille at the work access opening and through a supply HEPA filter. Approximately 70% of the HEPA-filtered air is circulated through the cabinet, while 30% passes through an exhaust HEPA filter and is discharged. These biohazard cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-ducted, these biological safety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research.

3' Purifier Logic Class II, Type A2 Biosafety Cabinet

Catalog # Summary
3430000 3' Nominal Width, Domestic Electrical Requirements
3430001 3' Nominal Width, Domestic Electrical Requirements, One
3430020 3' Nominal Width, International Electrical Requirements, British (UK)
3430021 3' Nominal Width, International Electrical Requirements, British (UK), One
3430022 3' Nominal Width, International Electrical Requirements, Schuko
3430023 3' Nominal Width, International Electrical Requirements, Schuko, One
3430024 3' Nominal Width, International Electrical Requirements, China/Australia
3430025 3' Nominal Width, International Electrical Requirements, China/Australia, One
3430026 3' Nominal Width, Domestic Electrical Requirements, North America, 230 volts
3430027 3' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, One
3430800 3' Nominal Width, Domestic Electrical Requirements
3430801 3' Nominal Width, Domestic Electrical Requirements, One
3430810 3' Nominal Width, International Electrical Requirements, 100 volts, 15 amps, One
3430811 3' Nominal Width, International Electrical Requirements, 100 volts, 15 amps, One
3430820 3' Nominal Width, International Electrical Requirements, British (UK)
3430821 3' Nominal Width, International Electrical Requirements, British (UK), One
3430822 3' Nominal Width, International Electrical Requirements, Schuko
3430823 3' Nominal Width, International Electrical Requirements, Schuko, One
3430824 3' Nominal Width, International Electrical Requirements, China/Australia
3430825 3' Nominal Width, International Electrical Requirements, China/Australia, One
3430826 3' Nominal Width, Domestic Electrical Requirements, North America, 230 volts
3430827 3' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, One

4' Purifier Logic Class II, Type A2 Biosafety Cabinet

Catalog # Summary
3440000 Domestic Electrical Requirements
3440001 Domestic Electrical Requirements, One
3440020 International Electrical Requirements, British (UK)
3440021 International Electrical Requirements, British (UK), One
3440022 International Electrical Requirements, Schuko
3440023 International Electrical Requirements, Schuko, One
3440024 International Electrical Requirements, China/Australia
3440025 International Electrical Requirements, China/Australia, One
3440026 Domestic Electrical Requirements, North America, 230 volts
3440027 Domestic Electrical Requirements, North America, 230 volts, One
3440800 Domestic Electrical Requirements
3440801 Domestic Electrical Requirements, One
3440810 International Electrical Requirements, 100 volts, 15 amps
3440811 International Electrical Requirements, 100 volts, 15 amps, One
3440820 International Electrical Requirements, British (UK)
3440821 International Electrical Requirements, British (UK), One
3440822 International Electrical Requirements, Schuko
3440823 International Electrical Requirements, Schuko, One
3440824 International Electrical Requirements, China/Australia
3440825 International Electrical Requirements, China/Australia, One
3440826 Domestic Electrical Requirements, North America, 230 volts
3440827 Domestic Electrical Requirements, North America, 230 volts, One
3440830 International Electrical Requirements, Schuko
3440831 International Electrical Requirements, Schuko, One

5' Purifier Logic Class II, Type A2 Biosafety Cabinet

Catalog # Summary
3450000 Domestic Electrical Requirements
3450001 Domestic Electrical Requirements, One
3450020 International Electrical Requirements, British (UK)
3450021 International Electrical Requirements, British (UK), One
3450022 International Electrical Requirements, Schuko
3450023 International Electrical Requirements, Schuko, One
3450024 International Electrical Requirements, China/Australia
3450025 International Electrical Requirements, China/Australia, One
3450026 Domestic Electrical Requirements, North America, 230 volts
3450027 Domestic Electrical Requirements, North America, 230 volts, One
3450800 Domestic Electrical Requirements
3450801 Domestic Electrical Requirements, One
3450810 International Electrical Requirements, 100 volts, 15 amps
3450811 International Electrical Requirements, 100 volts, 15 amps, One
3450820 International Electrical Requirements, British (UK)
3450821 International Electrical Requirements, British (UK), One
3450822 International Electrical Requirements, Schuko
3450823 International Electrical Requirements, Schuko, One
3450824 International Electrical Requirements, China/Australia
3450825 International Electrical Requirements, China/Australia, One
3450826 Domestic Electrical Requirements, North America, 230 volts
3450827 Domestic Electrical Requirements, North America, 230 volts, One

6' Purifier Logic Class II, Type A2 Biosafety Cabinet

Catalog # Summary
3460000 6' Nominal Width, Domestic Electrical Requirements
3460001 6' Nominal Width, Domestic Electrical Requirements, Two
3460020 6' Nominal Width, International Electrical Requirements, British (UK)
3460021 6' Nominal Width, International Electrical Requirements, British (UK), Two
3460022 6' Nominal Width, International Electrical Requirements, Schuko
3460023 6' Nominal Width, International Electrical Requirements, Schuko, Two
3460024 6' Nominal Width, International Electrical Requirements, China/Australia
3460025 6' Nominal Width, International Electrical Requirements, China/Australia, Two
3460026 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts
3460027 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two
3460800 6' Nominal Width, Domestic Electrical Requirements
3460801 6' Nominal Width, Domestic Electrical Requirements, Two
3460810 6' Nominal Width, International Electrical Requirements, 100 volts, 20 amps
3460811 6' Nominal Width, International Electrical Requirements, 100 volts, 20 amps, Two
3460820 6' Nominal Width, International Electrical Requirements, British (UK)
3460821 6' Nominal Width, International Electrical Requirements, British (UK), Two
3460822 6' Nominal Width, International Electrical Requirements, Schuko
3460823 6' Nominal Width, International Electrical Requirements, Schuko, Two
3460824 6' Nominal Width, International Electrical Requirements, China/Australia
3460825 6' Nominal Width, International Electrical Requirements, China/Australia, Two
3460826 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts
3460827 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two
Purifier Safety Enclosures, Clean Benches & Non-Ventilated Enclosures Catalog Contains information on Purifier Class I and HEPA-Filtered Enclosures, Purifier Horizontal and Vertical Clean Benches, Purifier Filtered PCR Enclosures, and Purifier Non-Ventilated PCR and Tissue Culture Enclosures.
download PDF (Login Required)
Purifier Logic Biosafety Cabinets Catalog Contains information on the Purifier Logic Class II, Type A2 and B2 Biosafety Cabinets and accessories.
download PDF (Login Required)
Personnel and Product Protection: A Guide To Biosafety Enclosures Industry service publication provides helpful information on choosing the right biological safety cabinet for your application. Types of cabinets and selection considerations are discussed.
download PDF (Login Required)
Biological Safety Cabinets Presentation This overview on biological safety cabinets covers theory of operation, cabinet types, cabinet type specification and industry trends. It is designed to help lab planners, facility managers and architects determine which biological safety cabinet to select for their laboratories.
download PDF (Login Required)
Purifier Logic Biosafety Cabinets Presentation Presentation provides an overview of the features and benefits and accessories of Purifier Logic Biosafety Cabinets. Working in a biosafety cabinet, maintenance, certification and operating procedures are also presented.
download PDF (Login Required)
Altitude Adjustment for Purifier Logic Biosafety Cabinets Answers to frequently asked questions in regard to altitude adjustment for Purifier Logic Biosafety Cabinets.
download PDF (Login Required)
Purifier Logic Class II Type A2 Biosafety Cabinet Manual For catalog numbers: 34300 Series, 34308 Series, 34400 Series, 34500 Series, 34408 Series, 34508 Series, 34600 Series, 34608 Series
download PDF (Login Required)
Navigating the Logic Certifier's Menu - Certifier Instructions
download PDF (Login Required)
Navigating the Logic Menu - User Instructions
download PDF (Login Required)
Technical Manual and Specifications for Purifier Logic Biosafety Cabinets and PuriCare Procedure Stations Provides detailed information for use in certifying or servicing Labconco biological safety cabinets.
download PDF (Login Required)
Wiring Diagram for the Purifier Logic Class II A2/B2 Biosafety Cabinet, 115 V 50/60Hz operation For Purifier Logic Class II, Type A2 Biosafety Cabinet and Purifier Logic Class II, Type B2 Biosafety Cabinet, 115 V 50/60Hz operation.
download PDF (Login Required)
Wiring Diagram for the Purifier Logic Class II A2/B2 Biosafety Cabinet, 230V 50/60Hz operation For Purifier Logic Class II, Type A2 Biosafety Cabinet and Purifier Logic Class II, Type B2 Biosafety Cabinet, 230V 50/60Hz operation.
download PDF (Login Required)
Purifier Logic Class II, Type A2 Biological Safety Cabinets Specifications
download TXT (Login Required)
Purifier Logic Class II, Type A2 Biosafety Cabinet CAD Dimensions are provided for 3', 4', 5' and 6' Purifier Logic Class II, Type A2 Biosafety Cabinets.
download DWG (Login Required)
download PDF (Login Required)
Purifier Logic Biosafety Cabinet Video This video demonstrates the features, benefits and operation of the Purifier Biosafety Cabinet.

To B2 or not to B2 — A Biological Safety Cabinet Story
download HTML
download PDF (Login Required)
Logically Controlling Airflow: Advantages of the Logic ECM
download HTML
download PDF (Login Required)
The Curved Air Foil of the Purifier Logic Biosafety Cabinet
download ASP
download PDF (Login Required)
Installation Qualification/Operation Qualification for Purifier Logic Biosafety Cabinets For validation of predetermined Purifier Logic Biosafety Cabinet specifications. Provides a checklist of installation and operation qualifications to complete when beginning operation on new or used Purifier Logic Biosafety Cabinets.
download PDF (Login Required)
The Advantages of Using an Electronically Commutated Motor (ECM) in Biosafety Cabinets This white paper explains the ECM motor in our Purifier Logic Biological Safety Cabinets and its advantages over PSC motors.
download PDF (Login Required)

Compliance

• NSF International Standard 49 for Biohazard Cabinetry
• UL Standard 61010-1
• CAN/CSA Standard C22.2 No. 1010.1
• CE conformity (230 volt models)

Features

• Nominal inflow velocity of 105 fpm (0.5 m/sec)
• Nominal downflow velocity of 55 fpm (0.3 m/sec)
• Patent-pending design
• Interior-mounted, line-of-sight LCD information center with "Filter Life Remaining" bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20%, 10% and 0%
• Filter monitoring system consisting of an electronically commutated motor (ECM) that delivers a precise volume of air as required and automatically adjusts as filters load without relying on airflow sensors
• Smart-Start™ System that allows the user to program start up and shut down operations
• Night-Smart™ System that idles the blower when the sash is fully closed
• Built-in interval or elapsed timer for experiment monitoring or UV light control (on models with UV light)
• Touchpad control on right-hand side post for manual activation of blower, light, timer, audible alarm mute and menu selection
• Radiused type 304 stainless steel interior and removable, seamless, dished work surface with lift out knobs
• Epoxy-coated steel exterior
• Towel catch located under work surface
• Contain-Air™ Negative Pressure Channel
• Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
• Supply and exhaust 99.99% efficient HEPA filters
• Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption and stainless steel splash covers
• Fully-closing, clear 1/4" tempered safety glass sash with two sash handles; counterbalanced, anti-racking mechanism; and 10° slope
• 29" sash opening viewing height
• Curved stainless steel inlet grille with Reserve-Air™ Secondary Airflow Slots
• Bright, 100 foot-candle, glare-free fluorescent lighting located outside the contaminated work area
• Intrinsically safe negative pressure design
• Electronic security lock (optional activation) that requires code to operate the cabinet
• Full three year warranty
• NSF-Listed
• ETL listed (115 volt, 60 Hz models)
• CE conformity (230 volt, 50 Hz models)
• EN 12469 compliant (3440830 and 3440831 models)

Options

• 3’, 4’, 5’ and 6’ widths
• 254 nm UV lamp
• Service fixture(s) with ball-type valve(s)
• International electrical configurations
• 99.999% ULPA filters. Contact Labconco for ordering information.

Required Accessories

Adjustable Height Base Stands