|| Products  >> HEPA Filtered Biological Safety Cabinets, Enclosures and Clean Benches  >> Class II, Type B2 Biological Safety Cabinets

Class II, Type B2 Biological Safety Cabinets

Purifier Logic Class II, Type B2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. All models are NSF-Listed.

These biological safety cabinets are designed to be hard ducted to the outside. During operation, room air is drawn into the top of the cabinet and through a supply HEPA filter. This filtered air flows downward through the work area. Room air is also drawn into the inlet grille located at the work access opening. All of the contaminated air passes through the exhaust HEPA filter. A dedicated exhaust system and remote blower discharge 100% of the filtered exhaust air from the laboratory. Since none of the air is recirculated, these biohazard cabinets may be used for work with agents treated with volatile toxic chemicals and radionuclides.

Filter Reminder Service Filter Reminder Service

Get an email reminder to check or change your filters! Set up reminder now.

4' Purifier Logic Class II, Type B2 Total Exhaust Biosafety Cabinet

Catalog # Summary
3441000 Domestic Electrical Requirements
3441001 Domestic Electrical Requirements, One
3441010 International Electrical Requirements, 100 volts, 15 amps
3441011 International Electrical Requirements, 100 volts, 15 amps, One
3441020 International Electrical Requirements, British (UK)
3441021 International Electrical Requirements, British (UK), One
3441022 International Electrical Requirements, Schuko
3441023 International Electrical Requirements, Schuko, One
3441024 International Electrical Requirements, China/Australia
3441025 International Electrical Requirements, China/Australia, One
3441026 Domestic Electrical Requirements, North America, 230 volts
3441027 Domestic Electrical Requirements, North America, 230 volts, One

6' Purifier Logic Class II, Type B2 Total Exhaust Biosafety Cabinet

Catalog # Summary
3461000 6' Nominal Width, Domestic Electrical Requirements, 100 volts, 20 amps
3461001 6' Nominal Width, Domestic Electrical Requirements, Two
3461010 6' Nominal Width, International Electrical Requirements, 100 volts, 20 amps
3461011 6' Nominal Width, International Electrical Requirements, 100 volts, 20 amps, Two
3461020 6' Nominal Width, International Electrical Requirements, British (UK)
3461021 6' Nominal Width, International Electrical Requirements, British (UK), Two
3461022 6' Nominal Width, International Electrical Requirements, Schuko
3461023 6' Nominal Width, International Electrical Requirements, Schuko, Two
3461024 6' Nominal Width, International Electrical Requirements, China/Australia
3461025 6' Nominal Width, International Electrical Requirements, China/Australia, Two
3461026 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts
3461027 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two
Purifier Safety Enclosures, Clean Benches & Non-Ventilated Enclosures Catalog Contains information on Purifier Class I and HEPA-Filtered Enclosures, Purifier Horizontal and Vertical Clean Benches, Purifier Filtered PCR Enclosures, and Purifier Non-Ventilated PCR and Tissue Culture Enclosures.
download PDF (Login Required)
Purifier Logic Biosafety Cabinets Catalog Contains information on the Purifier Logic Class II, Type A2 and B2 Biosafety Cabinets and accessories.
download PDF (Login Required)
Personnel and Product Protection: A Guide To Biosafety Enclosures Industry service publication provides helpful information on choosing the right biological safety cabinet for your application. Types of cabinets and selection considerations are discussed.
download PDF (Login Required)
Biological Safety Cabinets Presentation This overview on biological safety cabinets covers theory of operation, cabinet types, cabinet type specification and industry trends. It is designed to help lab planners, facility managers and architects determine which biological safety cabinet to select for their laboratories.
download PDF (Login Required)
Purifier Logic Biosafety Cabinets Presentation Presentation provides an overview of the features and benefits and accessories of Purifier Logic Biosafety Cabinets. Working in a biosafety cabinet, maintenance, certification and operating procedures are also presented.
download PDF (Login Required)
Purifier Logic Class II Type B2 Biosafety Cabinet Manual For catalog numbers: 34410 Series, 34610 Series
download PDF (Login Required)
Altitude Adjustment for Purifier Logic Biosafety Cabinets Answers to frequently asked questions in regard to altitude adjustment for Purifier Logic Biosafety Cabinets.
download PDF (Login Required)
Purifier Logic Bag-In Bag-Out Assembly Instructions
Outlines the procedure for assembling the bag-in bag-out filter replacement system on a Purifier Logic Biosafety Cabinet or Purifier Cell Logic Biosafety Cabinet.
download PDF (Login Required)
Purifier Logic Unpacking Instructions Outlines the procedure for unpacking a Purifier Logic or Purifier Cell Logic Biosafety Cabinet.
download PDF (Login Required)
Wiring Diagram for the Purifier Logic Class II A2/B2 Biosafety Cabinet, 115 V 50/60Hz operation For Purifier Logic Class II, Type A2 Biosafety Cabinet and Purifier Logic Class II, Type B2 Biosafety Cabinet, 115 V 50/60Hz operation.
download PDF (Login Required)
Wiring Diagram for the Purifier Logic Class II A2/B2 Biosafety Cabinet, 230V 50/60Hz operation For Purifier Logic Class II, Type A2 Biosafety Cabinet and Purifier Logic Class II, Type B2 Biosafety Cabinet, 230V 50/60Hz operation.
download PDF (Login Required)
Technical Manual and Specifications for Purifier Logic Biosafety Cabinets and PuriCare Procedure Stations Provides detailed information for use in certifying or servicing Labconco biological safety cabinets.
download PDF (Login Required)
Navigating the Logic Certifier's Menu - Certifier Instructions
download PDF (Login Required)
Navigating the Logic Menu - User Instructions
download PDF (Login Required)
Purifier Logic Class II, Type B2 Biological Safety Cabinets Specifications are provided for 4' and 6' Purifier Logic Class II, Type B2 Biosafety Cabinets.
download TXT (Login Required)
Purifier Logic Class II, Type B2 Biosafety Cabinets CAD Dimensions are provided for 4' and 6' Purifier Logic Class II, Type B2 Biosafety Cabinets.
download DWG (Login Required)
download PDF (Login Required)
Purifier Logic Biosafety Cabinet Video This video demonstrates the features, benefits and operation of the Purifier Biosafety Cabinet.

Biological Safety Cabinets & Enclosures Selection Guide

Selection guide presents a comparison of the features, available options and potential applications for Labconco''s range of Class II and Class I Biological Safety Cabinets & Enclosures.

download PDF (Login Required)
To B2 or not to B2 — A Biological Safety Cabinet Story
download HTML
download PDF (Login Required)
Logically Controlling Airflow: Advantages of the Logic ECM
download HTML
download PDF (Login Required)
The Curved Air Foil of the Purifier Logic Biosafety Cabinet
download HTML
download PDF (Login Required)
CETA offers a new guide on Class II, Type B2 Biosafety Cabinets
download HTML
download PDF (Login Required)
Manifolding (Ganging) Class II B2 Biological Safety Cabinets
download HTML
download PDF (Login Required)
Installation Qualification/Operation Qualification for Purifier Logic Biosafety Cabinets For validation of predetermined Purifier Logic Biosafety Cabinet specifications. Provides a checklist of installation and operation qualifications to complete when beginning operation on new or used Purifier Logic Biosafety Cabinets.
download PDF (Login Required)
The Advantages of Using an Electronically Commutated Motor (ECM) in Biosafety Cabinets This white paper explains the ECM motor in our Purifier Logic Biological Safety Cabinets and its advantages over PSC motors.
download PDF (Login Required)
Controlling Airflow in Class II Biosafety Cabinets This white paper reviews the current technologies used by various biosafety cabinet manufacturers to monitor and maintain proper airflows as HEPA filters load.
download PDF (Login Required)
CAG-007-2010 Application Guide for Exhaust System Requirements of Class II, Type B Biosafety Cabinets This publication by Controlled Environment Testing Association (CETA) provides a comparison of Class II, Type A versus Type B biological safety cabinets, selection criteria, site requirements and other considerations.
download PDF (Login Required)

Compliance

• NSF International Standard 49 for Biohazard Cabinetry
• UL Standard 61010-1
• CAN/CSA Standard C22.2 No. 1010.1
• CE conformity (230 volt models)

Features

• Nominal inflow velocity of 105 fpm (0.5 m/sec)
• Nominal downflow velocity of 55 fpm (0.3 m/sec)
• Patent-pending design
• Interior-mounted, line-of-sight LCD information center with "Filter Life Remaining" bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20%, 10% and 0%
• Filter monitoring system consisting of an electronically commutated motor (ECM) that delivers a precise volume of air as required and automatically adjusts as filters load without relying on airflow sensors
• Smart-Start™ System that allows the user to program start up and shut down operations
• Built-in interval or elapsed timer for experiment monitoring or UV light control (on models with UV light)
• Touchpad control on right-hand side post for manual activation of blower, light, timer, audible alarm mute and menu selection
• Radiused type 304 stainless steel interior and removable, seamless, dished work surface with lift out knobs
• Epoxy-coated steel exterior
• Towel catch located under work surface
• Contain-Air™ Negative Pressure Channel
• Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100)
• Supply and exhaust 99.99% efficient HEPA filters
• Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption and stainless steel splash covers
• Fully-closing, clear 1/4" tempered safety glass sash with two sash handles; counterbalanced, anti-racking mechanism; and 10° slope
• 29" sash opening viewing height
• Curved stainless steel inlet grille with Reserve-Air™ Secondary Airflow Slots
• Bright, 100 foot-candle, glare-free fluorescent lighting located outside the contaminated work area
• Intrinsically safe negative pressure design
• Electronic security lock (optional activation) that requires code to operate the cabinet
• 10" diameter exhaust outlet
• Full three year warranty
• NSF-Listed
• ETL listed (115 volt, 60 Hz models)
• CE conformity (230 volt, 50 Hz models)

Options

• 4’ and 6’ nominal widths
• 254 nm UV lamp
• Service fixture(s) with ball-type valve(s)
• International electrical configurations
• 99.999% ULPA filters. Contact Labconco for ordering information.

Required Accessories

Remote Blowers
Adjustable Height Base Stands