Class II, Type B2 Biological Safety Cabinets
Purifier Logic Class II, Type B2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. All models are NSF-Listed.
These biological safety cabinets are designed to be hard ducted to the outside. During operation, room air is drawn into the top of the cabinet and through a supply HEPA filter. This filtered air flows downward through the work area. Room air is also drawn into the inlet grille located at the work access opening. All of the contaminated air passes through the exhaust HEPA filter. A dedicated exhaust system and remote blower discharge 100% of the filtered exhaust air from the laboratory. Since none of the air is recirculated, these biohazard cabinets may be used for work with agents treated with volatile toxic chemicals and radionuclides.
4' Purifier Logic Class II, Type B2 Total Exhaust Biosafety Cabinet |
||
| Catalog # | Summary | |
| 3441000 | Domestic Electrical Requirements | |
| 3441001 | Domestic Electrical Requirements, One | |
| 3441010 | International Electrical Requirements, 100 volts, 15 amps | |
| 3441011 | International Electrical Requirements, 100 volts, 15 amps, One | |
| 3441020 | International Electrical Requirements, British (UK) | |
| 3441021 | International Electrical Requirements, British (UK), One | |
| 3441022 | International Electrical Requirements, Schuko | |
| 3441023 | International Electrical Requirements, Schuko, One | |
| 3441024 | International Electrical Requirements, China/Australia | |
| 3441025 | International Electrical Requirements, China/Australia, One | |
| 3441026 | Domestic Electrical Requirements, North America, 230 volts | |
| 3441027 | Domestic Electrical Requirements, North America, 230 volts, One | |
6' Purifier Logic Class II, Type B2 Total Exhaust Biosafety Cabinet |
||
| Catalog # | Summary | |
| 3461000 | 6' Nominal Width, Domestic Electrical Requirements, 100 volts, 20 amps | |
| 3461001 | 6' Nominal Width, Domestic Electrical Requirements, Two | |
| 3461010 | 6' Nominal Width, International Electrical Requirements, 100 volts, 20 amps | |
| 3461011 | 6' Nominal Width, International Electrical Requirements, 100 volts, 20 amps, Two | |
| 3461020 | 6' Nominal Width, International Electrical Requirements, British (UK) | |
| 3461021 | 6' Nominal Width, International Electrical Requirements, British (UK), Two | |
| 3461022 | 6' Nominal Width, International Electrical Requirements, Schuko | |
| 3461023 | 6' Nominal Width, International Electrical Requirements, Schuko, Two | |
| 3461024 | 6' Nominal Width, International Electrical Requirements, China/Australia | |
| 3461025 | 6' Nominal Width, International Electrical Requirements, China/Australia, Two | |
| 3461026 | 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts | |
| 3461027 | 6' Nominal Width, Domestic Electrical Requirements, North America, 230 volts, Two | |
Compatible Products
Main ProductsLaboratory Carts, Tables & Benches
Accessories
Base Stands and Accessories
Biosafety Cabinet & Procedure Station Accessories
Ductwork and Blower Accessories
Filters, Prefilters and Accessories
General Accessories
Purifier Cell Logic Accessories
Remote Blowers
Utility Shelf Accessories
Work Surfaces and Accessories
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Selection guide presents a comparison of the features, available options and potential applications for Labconco''s range of Class II and Class I Biological Safety Cabinets & Enclosures.
|
|
|
|
|
|
|
|
|
|
Compliance
|
• NSF International Standard 49 for Biohazard Cabinetry |
Features
|
• Nominal inflow velocity of 105 fpm (0.5 m/sec) |
Options
|
• 4’ and 6’ nominal widths |









