|| Products  >> Glove Boxes  >> XPert Weigh Boxes

XPert Weigh Boxes

XPert Weigh Boxes have inlet and outlet HEPA filters and provide a leak-tight physical barrier to protect the operator from hazardous airborne particulates and powders. These boxes include an anti-static ionizer fan to reduce static charge and a balance vibration isolator, both useful during weighing operations.

Filter Reminder Service Filter Reminder Service

Get an email reminder to check or change your filters! Set up reminder now.

XPert Weigh Boxes

Catalog # Summary
5220300 Domestic Electrical Requirements
5220320 International Electrical Requirements
5220321 Domestic Electrical Requirements
5220330 International Electrical Requirements
5220331 International Electrical Requirements
Protector Glove Boxes Catalog Contains specifications, dimensional drawings and ordering information on Labconco's line of Protector Controlled Atmosphere and Multi-Hazard Glove Boxes.
download PDF (Login Required)
Precise Glove Boxes Catalog Contains specifications, dimensional drawings and ordering information on Labconco's line of Precise Glove Boxes and XPert Weigh Boxes.
download PDF (Login Required)
Precise Glove Box Overview Presentation Provides general information on Precise Basic, Controlled Atmosphere and HEPA-Filtered Glove Boxes and XPert Weigh Box Glove Boxes. Answers basic questions and discusses the features and benefits of Precise Glove Boxes. Also addresses accessories available and market applications for Precise Glove Boxes.
download PDF (Login Required)
Protector Glove Box Overview Presentation Provides general information on Protector Controlled Atmosphere, Multi-Hazard and Combination Glove Boxes. Answers basic questions and discusses the features and benefits of Protector Glove Boxes. Also addresses accessories, market applications and the American Glove Box Society.
download PDF (Login Required)
Precise HEPA-Filtered Glove Box and XPert Weigh Box Performance Test Report Results of performance tests conducted on Precise HEPA-Filtered Glove Box and XPert Weigh Box
download PDF (Login Required)
Performance Verification of the Precise HEPA-Filtered Glove Box Report details the test procedure and results of measuring the ability of Precise HEPA-Filtered Glove boxes to contain powders, using naproxen sodium as the surrogate for the study.
download PDF (Login Required)
Glove Box Viewing Window and Gasket Replacement Instructions Outlines the replacement procedure for the viewing window and gaskets on all Labconco glove boxes.
download PDF (Login Required)
XPert Weigh Boxes Manual For catalog numbers: 5220300, 5220320, 5220321, 5220330, 5220331
download PDF (Login Required)
Precise HEPA-Filtered Glove Boxes and XPert Weigh Boxes Specifications
download TXT (Login Required)
XPert Weigh Boxes CAD
download DWG (Login Required)
download PDF (Login Required)
XPert Weigh Boxes SketchUp 3D CAD In order to view 3D CAD Drawings, download and install the Google Sketchup Viewer from sketchup.google.com The application will prompt you through the installation process.
download SKP (Login Required)
How It Works: High Containment at Low Cost Lab Manager, September 2007 article describes why the Precise Glove Box makes sense for laboratories with a tight budget.
download PDF (Login Required)
Just how precise is the Precise Glove Box?
download HTML
download PDF (Login Required)
Testing the XPert® Weigh Box for Vibration
download HTML
download PDF (Login Required)
An Amateur's Guide to the XPert Family Tree
download HTML
download PDF (Login Required)
Installation Qualification/Operation Qualification for Precise HEPA Filtered Glove Box, Precise XPert Weigh Glove Box For validation of predetermined Precise HEPA Filtered Glove Box and Precise XPert Weigh Glove Box. Provides a checklist of installation and operation qualifications to complete when beginning operation on new or used Precise HEPA Filtered Glove Box and Precise XPert Weigh Glove Box.
download PDF (Login Required)

Features

• One-piece molded, medium-density polyethylene shell. Labconco recommends this website for a comprehensive listing of chemical resistance data for polyethylene.
• Dry powder epoxy-coated steel superstructure
• 1/4" thick laminated safety glass viewing window, 26.4" wide x 12.5" high, removable for loading equipment, with powder-coated steel frame and neoprene gasket
• Space-saving inner and outer transfer chamber doors that pivot upward, are counterbalanced and equipped with quick-latches
• Black, chemical-resistant work surface sealed to the glove box floor
• Anti-static ionizer fan to circulate ionized air inside the box to reduce static charge during weighing
• Interior ceiling-mounted electrical duplex receptacle with 5 amp maximum circuit load
• Neoprene gloves, size 9 3/4", are included.
• Built-in blower with speed control capable of airflow from 13 CFM to 100 CFM.
• Fluorescent lamp, 22 watts, with easy replacement from the top
• Switches for light, blower and innermost interior electrical receptacle
• Inlet and outlet HEPA filters, 99.99% efficient on 0.3 micron particulates
• Test port for challenging HEPA filter integrity
• Main chamber static pressure gauge for monitoring HEPA filter loading.
• Approximately 13 cubic feet of interior space in main chamber
• 11.0" nominal ID x 12.0" long transfer chamber
• Factory leak tested with a mass spectrometer while glove box is pressurized with helium at 5 inches of water gauge
• No detectable leaks greater than 1 x 10(-3) ml/sec
• Meet Class 1 atmosphere containment conditions for oxygen leak rates per ISO 10648-2 test method
• Transfer chamber interior interlocking shelf of dry powder epoxy-coated steel
• 0.05 ppm average tracer gas levels or less detected during perimeter scan testing (surpasses ASHRAE 110 standards)
• Airborne particulate cleanliness (measured under positive and negative pressures per ISO 14644-1 test method) exceeds ISO Class 5 conditions (equivalent to Class 100) and achieved ISO Class 3 conditions (equivalent to Class 1) at both minimum and maximum operational airflow volumes
• Vibration less than 1.5 x 10(-5) inches displacement measured at the work surface at both minimum and maximum airflow volumes
• ETL listed (115 volt models)
• CE Conformity (230 volt models)

Options

• International electrical configurations

Required Accessories

Adjustable Height Base Stands
Base Cabinet
Work Surface

Optional Accessories

• Acrylic Viewing Window
• Add-A-Valve Kit
• Anti-Static Ionizer Fan
• Balance Vibration Isolator
• Blower Foot Switch
• Complete Valve Set
Diaphragm Pumps
• Electrical Power Strips
• Exterior Transfer Chamber Shelf
• External Glove Port Covers
• FilterMate Portable Exhausters
Gloves and Glove Box Accessories
• Hanging Shelf Accessories
• Positive Pressure Conversion Kit
• Recirculation Kit
• Remote Blowers
• Storage Shelf Kits
• Trap Inserts
• Waste Chute